{"id":12864,"date":"2023-07-10T12:28:32","date_gmt":"2023-07-10T11:28:32","guid":{"rendered":"https:\/\/www.mydatec.com\/?page_id=12864"},"modified":"2023-07-18T08:56:03","modified_gmt":"2023-07-18T07:56:03","slug":"entretien-du-puits-canadien-hydraulique-mydatec","status":"publish","type":"page","link":"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/","title":{"rendered":"puits canadien hydraulique de MyDATEC- entretien"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container hundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--link_hover_color: #768e20;--link_color: #768e20;--awb-border-sizes-top:0;--awb-border-sizes-bottom:0;--awb-border-sizes-left:0;--awb-border-sizes-right:0;--awb-border-color:#ffffff;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:35px;--awb-padding-right:35px;--awb-padding-bottom:90px;--awb-padding-left:35px;--awb-padding-top-medium:25px;--awb-padding-right-medium:25px;--awb-padding-left-medium:25px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-margin-bottom-medium:70px;--awb-margin-bottom-small:60px;--awb-background-color:#ffffff;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-padding-top:10vw;--awb-padding-right:10vw;--awb-padding-bottom:10vw;--awb-padding-left:10vw;--awb-padding-top-medium:60px;--awb-padding-right-medium:60px;--awb-padding-bottom-medium:60px;--awb-padding-left-medium:60px;--awb-overflow:hidden;--awb-bg-image:url(&#039;https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-13-a-10.38.00.png&#039;);--awb-bg-position:center center;--awb-bg-blend:multiply;--awb-bg-size:cover;--awb-border-radius:20px 20px 20px 20px;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column fusion-column-has-bg-image\" data-bg-url=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-13-a-10.38.00.png\"><div class=\"fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-center fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-0 fusion_builder_column_inner_1_1 1_1 fusion-flex-column fusion-animated\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:3.84%;--awb-spacing-left-medium:3.84%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-margin-bottom-small:50px;--awb-spacing-left-small:1.92%;\" data-animationType=\"fadeInUp\" data-animationDuration=\"1.3\" data-animationOffset=\"top-into-view\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-one\" style=\"--awb-text-color:var(--awb-color1);--awb-margin-bottom:30px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:50px;\"><h1 class=\"fusion-title-heading title-heading-center\" style=\"font-family:&quot;Kaisei Decol&quot;;font-style:normal;font-weight:500;margin:0;letter-spacing:var(--awb-typography1-letter-spacing);text-transform:var(--awb-typography1-text-transform);font-size:1em;line-height:1.2;\"><p style=\"text-align: center;\"><span style=\"color: #ffffff;\"><strong>Entretien du puits canadien hydraulique MyDATEC<\/strong><\/span><\/p><\/h1><\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-custom fusion-button-default button-1 fusion-button-default-span \" style=\"--awb-padding-top:20px;--awb-padding-right:60px;--awb-padding-bottom:20px;--awb-padding-left:60px;--button_accent_color:#000000;--button_border_color:#000000;--button_accent_hover_color:#596301;--button_border_hover_color:#768e20;--button_border_width-top:0px;--button_border_width-right:0px;--button_border_width-bottom:0px;--button_border_width-left:0px;--button-border-radius-top-left:50px;--button-border-radius-top-right:50px;--button-border-radius-bottom-right:50px;--button-border-radius-bottom-left:50px;--button_gradient_top_color:#ffffff;--button_gradient_bottom_color:#ffffff;--button_gradient_top_color_hover:#ffffff;--button_gradient_bottom_color_hover:#ffffff;--button_text_transform:var(--awb-typography3-text-transform);--button_font_size:20px;--button_line_height:1.7;--button_typography-letter-spacing:0px;--button_typography-font-family:&quot;Roboto&quot;;--button_typography-font-style:normal;--button_typography-font-weight:500;\" target=\"_self\" href=\"https:\/\/f0c4e0af.sibforms.com\/serve\/MUIFAK2G7qSgPZRHuaB9v54K-XWjekAp1VcrjOpKfFUMbe7rQ10_LH_ahDcneIHfwbLafRmYExBRGgYhS7Y_BY6koRrIFKMyAML3AZREc1iGgJlbjJVvoN75oGRdRuZAqjIBrSVjnHETCRzqIm5k51xG7WxiNlH0N_DYiKjF-flAcUu-jhRkR_DY36iKfPR8ZNG3l1CAzcfA2gHc\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">D\u00e9couvrir notre solution de puits canadien \u00e0 eau<\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1144px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><nav class=\"fusion-breadcrumbs awb-yoast-breadcrumbs fusion-breadcrumbs-1\" style=\"--awb-margin-bottom:50;--awb-alignment:left;--awb-breadcrumb-sep:&#039;\/&#039;;text-align:left;\" aria-label=\"Breadcrumb\"><ol class=\"awb-breadcrumb-list\"><li class=\"fusion-breadcrumb-item\"  aria-hidden=\"true\"><span  class=\"fusion-breadcrumb-prefix\">Revenir \u00e0 la section pr\u00e9c\u00e9dente:<\/span><\/li><li class=\"fusion-breadcrumb-item awb-breadcrumb-sep awb-home\" ><a href=\"https:\/\/www.mydatec.com\/fr\/\" class=\"fusion-breadcrumb-link\"><span >Home<\/span><\/a><\/li><\/ol><\/nav><div class=\"fusion-text fusion-text-1\" style=\"--awb-margin-top:20px;\"><p>Retourner \u00e0 la page g\u00e9n\u00e9rale: <a href=\"https:\/\/www.mydatec.com\/fr\/puits-canadien-hydraulique-mydatec\/\">le puits canadien hydraulique MyDATEC<\/a><\/p>\n<\/div><div class=\"fusion-text fusion-text-2 fusion-text-no-margin\" style=\"--awb-margin-top:60px;--awb-margin-bottom:10px;\"><div class=\"page\" title=\"Page 24\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Tout savoir sur l&rsquo;Entretien du puits canadien hydraulique de MyDATEC:<\/p>\n<p>Un entretien et une maintenance pe\u0301riodique est obligatoire pour assurer le bon fonctionnement de votre puits canadien hydraulique MyDATEC.\u00a0Mais pas de panique, c&rsquo;est tr\u00e8s simple. Nous vous expliquons tout ici:<\/p>\n<p>Notez que pour faire durer le plus longtemps possible la dur\u00e9e de vie de votre installation de puits climatique hydraulique au cours des anne\u0301es, nous recommandons de conclure un contrat de maintenance avec une entreprise de maintenance (\u00e0 la port\u00e9e de tout chauffagiste ou climaticien).<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--link_hover_color: #768e20;--link_color: #768e20;--awb-border-sizes-top:0px;--awb-border-sizes-bottom:0px;--awb-border-sizes-left:0px;--awb-border-sizes-right:0px;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:100px;--awb-padding-right:80px;--awb-padding-bottom:100px;--awb-padding-left:80px;--awb-padding-top-small:60px;--awb-padding-bottom-small:60px;--awb-margin-top:0px;--awb-margin-bottom:0px;--awb-margin-bottom-medium:70px;--awb-margin-bottom-small:60px;--awb-background-color:#0d0f01;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-center fusion-flex-content-wrap\" style=\"max-width:calc( 1100px + 120px );margin-left: calc(-120px \/ 2 );margin-right: calc(-120px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:60px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:60px;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:60px;--awb-spacing-left-medium:60px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:60px;--awb-spacing-left-small:60px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#ffffff;--awb-margin-top:10px;--awb-margin-bottom:30px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:46px;\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Kaisei Decol&quot;;font-style:normal;font-weight:500;margin:0;letter-spacing:var(--awb-typography1-letter-spacing);text-transform:var(--awb-typography1-text-transform);font-size:1em;line-height:1.2;\"><div class=\"page\" title=\"Page 24\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #ffffff;\"><strong>L&rsquo;entretien du puits canadien hydraulique par l&rsquo;utilisateur final :<\/strong><\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/h2><\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"232\" title=\"utilisateur\" src=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/utilisateur-300x232.png\" alt class=\"img-responsive wp-image-13035\" srcset=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/utilisateur-200x154.png 200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/utilisateur-400x309.png 400w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/utilisateur-600x463.png 600w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/utilisateur-800x618.png 800w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/utilisateur-1200x927.png 1200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/utilisateur.png 1414w\" sizes=\"(max-width: 900px) 100vw, (max-width: 640px) 100vw, 1200px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-3 fusion-text-no-margin\" style=\"--awb-font-size:20px;--awb-line-height:1.7;--awb-letter-spacing:0px;--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-color:rgba(255,255,255,0.72);--awb-margin-right:120px;--awb-margin-bottom:45px;--awb-text-font-family:&quot;Roboto&quot;;--awb-text-font-style:normal;--awb-text-font-weight:400;\"><div class=\"page\" title=\"Page 24\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ul>\n<li><span style=\"color: #ffffff;\">\u00a0Remplacement du filtre; =&gt; tous les 6 mois<\/span><\/li>\n<li><span style=\"color: #ffffff;\">\u00a0 Nettoyage du drain de condensa =&gt; tous les 3 mois<\/span><\/li>\n<li><span style=\"color: #ffffff;\">\u00a0 Contro\u0302le de la pression hydraulique du circuit 2 bars =&gt; tous les ans<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_3 1_3 fusion-flex-column fusion-flex-align-self-flex-start\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:60px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:60px;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:60px;--awb-spacing-left-medium:60px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:60px;--awb-spacing-left-small:60px;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-block\"><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#0d0f01;--awb-margin-bottom:30px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:46px;\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Kaisei Decol&quot;;font-style:normal;font-weight:500;margin:0;letter-spacing:var(--awb-typography1-letter-spacing);text-transform:var(--awb-typography1-text-transform);font-size:1em;line-height:1.2;\"><div class=\"page\" title=\"Page 25\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<h3><span style=\"color: #ffffff;\"><strong>Remplacement du Filtre<\/strong><\/span><\/h3>\n<\/div>\n<\/div>\n<\/div><\/h2><\/div><div class=\"fusion-image-element in-legacy-container\" style=\"--awb-margin-top:115px;--awb-margin-bottom:30px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"189\" alt=\"Entretien du puits canadien hydraulique Mydatec filtres\" title=\"Entretien du puits canadien hydraulique Mydatec filtres\" src=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-03-a-15.15.48-300x189.png\" class=\"img-responsive wp-image-12885\" srcset=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-03-a-15.15.48-200x126.png 200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-03-a-15.15.48-400x252.png 400w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-03-a-15.15.48-600x379.png 600w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-03-a-15.15.48-800x505.png 800w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Capture-decran-2023-07-03-a-15.15.48.png 1046w\" sizes=\"(max-width: 900px) 100vw, (max-width: 640px) 100vw, 400px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-4 fusion-text-no-margin\" style=\"--awb-font-size:20px;--awb-line-height:1.5;--awb-letter-spacing:0px;--awb-text-transform:var(--awb-typography4-text-transform);--awb-text-color:#ffffff;--awb-margin-right:15%;--awb-margin-bottom:40px;--awb-margin-left:0px;--awb-text-font-family:&quot;Roboto&quot;;--awb-text-font-style:normal;--awb-text-font-weight:400;\"><div class=\"page\" title=\"Page 25\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #ffffff;\">La pe\u0301riodicite\u0301 de remplacement du filtre de\u0301pend des caracte\u0301ristiques de l\u2019air neuf entrant aspire\u0301 par votre syste\u0300me de ventilation.<\/span><\/p>\n<p><span style=\"color: #ffffff;\">Nous recommandons de remplacer ce filtre en me\u0302me temps que les filtres de votre unite\u0301 de ventilation et au moins tous les 6 mois.<\/span><\/p>\n<ol>\n<li><span style=\"color: #ffffff;\">Arre\u0302ter votre unite\u0301 de ventilation<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Mettre votre puits climatique hydraulique hors tension.<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Ouvrir le panneau en fac\u0327ade<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Tirer le filtre positionne\u0301 en (A) ou (B) en fonction du co\u0302te\u0301 d\u2019arrive\u0301e d\u2019air neuf<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Inse\u0301rer le filtre neuf<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Fermer le panneau de fac\u0327ade<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Remettre votre syste\u0300me sous tension.<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Remettre votre unite\u0301 de ventilation en fonctionnement<\/span>\n<div class=\"layoutArea\">\n<div class=\"column\"><\/div>\n<\/div>\n<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_3 1_3 fusion-flex-column fusion-flex-align-self-flex-start\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:60px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:60px;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:60px;--awb-spacing-left-medium:60px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:60px;--awb-spacing-left-small:60px;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-4 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#0d0f01;--awb-margin-bottom:30px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:46px;\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Kaisei Decol&quot;;font-style:normal;font-weight:500;margin:0;letter-spacing:var(--awb-typography1-letter-spacing);text-transform:var(--awb-typography1-text-transform);font-size:1em;line-height:1.2;\"><div class=\"page\" title=\"Page 25\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<h3><span style=\"color: #ffffff;\"><strong>Nettoyage des condensats<\/strong><\/span><\/h3>\n<\/div>\n<\/div>\n<\/div><\/h2><\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:30px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"199\" alt=\"Entretien du puits canadien hydraulique Mydatec condensats\" title=\"Entretien du puits canadien hydraulique Mydatec condensats\" src=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/condenstats-300x199.png\" class=\"img-responsive wp-image-13027\" srcset=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/condenstats-200x132.png 200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/condenstats-400x265.png 400w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/condenstats-600x397.png 600w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/condenstats-800x530.png 800w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/condenstats-1200x794.png 1200w\" sizes=\"(max-width: 900px) 100vw, (max-width: 640px) 100vw, 400px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-5\" style=\"--awb-font-size:20px;--awb-line-height:1.5;--awb-text-color:#ffffff;--awb-text-font-family:&quot;Roboto&quot;;--awb-text-font-style:normal;--awb-text-font-weight:400;\"><div class=\"page\" title=\"Page 26\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #ffffff;\">A ve\u0301rifier au minimum tous les 3 mois<\/span><\/p>\n<ol>\n<li><span style=\"color: #ffffff;\">Mettre votre puits climatique hydraulique hors tension.<\/span><\/li>\n<li><span style=\"color: #ffffff;\">De\u0301visser le siphon d\u2019e\u0301vacuation<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Nettoyer le siphon &amp; ve\u0301rifier l\u2019e\u0301coulement a\u0300 travers le siphon.<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Ve\u0301rifier la contenance en eau du siphon (doit e\u0302tre rempli)<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Remettre en place le siphon<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Remettre votre syste\u0300me sous tension<\/span><\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_3 1_3 fusion-flex-column fusion-flex-align-self-flex-start\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:60px;--awb-margin-bottom-large:20px;--awb-spacing-left-large:60px;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:60px;--awb-spacing-left-medium:60px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:60px;--awb-spacing-left-small:60px;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-5 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#0d0f01;--awb-margin-bottom:30px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:46px;\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Kaisei Decol&quot;;font-style:normal;font-weight:500;margin:0;letter-spacing:var(--awb-typography1-letter-spacing);text-transform:var(--awb-typography1-text-transform);font-size:1em;line-height:1.2;\"><div class=\"page\" title=\"Page 25\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<h3><span style=\"color: #ffffff;\"><strong>V\u00e9rification du circuit hydraulique.<\/strong><\/span><\/h3>\n<\/div>\n<\/div>\n<\/div><\/h2><\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-margin-top:30px;--awb-margin-bottom:30px;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"200\" alt=\"Entretien du puits canadien hydraulique Mydatec pression\" title=\"Entretien du puits canadien hydraulique Mydatec pression\" src=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/barometre-300x200.png\" class=\"img-responsive wp-image-13029\" srcset=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/barometre-200x133.png 200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/barometre-400x267.png 400w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/barometre-600x400.png 600w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/barometre-800x533.png 800w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/barometre-1200x800.png 1200w\" sizes=\"(max-width: 900px) 100vw, (max-width: 640px) 100vw, 400px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-6\" style=\"--awb-font-size:20px;--awb-line-height:1.5;--awb-text-color:#ffffff;--awb-text-font-family:&quot;Roboto&quot;;--awb-text-font-style:normal;--awb-text-font-weight:400;\"><div class=\"page\" title=\"Page 26\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #ffffff;\">A ve\u0301rifier au minimum tous les ans<\/span><\/p>\n<p><span style=\"color: #ffffff;\">Ve\u0301rifier la valeur de pression a\u0300 l\u2019aide du manome\u0300tre 0.8bar \/ 2.5bar. Faire un comple\u0301ment d\u2019eau si ne\u0301cessaire. La pression hydraulique doit e\u0302tre comprise entre 0.8 et 2.5bar afin d\u2019assurer un fonctionnement normal. La pression optimale de fonctionnement est de 2 bars.<\/span><\/p>\n<p><span style=\"color: #ffffff;\">Voil\u00e0 comment faire un compl\u00e9ment d&rsquo;eau:<\/span><\/p>\n<ol>\n<li><span style=\"color: #ffffff;\">Mettre votre puits climatique hydraulique hors tension.<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Ouvrir la trappe d\u2019acce\u0300s a\u0300 la partie hydraulique (capot supe\u0301rieur).<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Connecter un tuyau a\u0300 la vanne (2).<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Ouvrir le\u0301ge\u0300rement la vanne (2) pour re\u0301cupe\u0301rer dans un re\u0301cipient une le\u0301ge\u0300re quantite\u0301 d\u2019eau glycole\u0301e provenant du circuit et refermer.<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Mesurer le pourcentage de glycol a\u0300 l\u2019aide d\u2019un refractome\u0300tre sur l\u2019e\u0301chantillon pre\u0301leve\u0301 du circuit.<\/span><\/li>\n<li><span style=\"color: #ffffff;\">Remplir le circuit suivant la proce\u0301dure.<\/span><\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1144px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-6 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"--awb-text-color:#ffffff;--awb-margin-top:10px;--awb-margin-bottom:30px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:46px;\"><h2 class=\"fusion-title-heading title-heading-left\" style=\"font-family:&quot;Kaisei Decol&quot;;font-style:normal;font-weight:500;margin:0;letter-spacing:var(--awb-typography1-letter-spacing);text-transform:var(--awb-typography1-text-transform);font-size:1em;line-height:1.2;\"><div class=\"page\" title=\"Page 24\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\"><strong>L&rsquo;entretien du puits canadien hydraulique <\/strong><\/span><span style=\"color: #333333;\"><strong>par un installateur \/ plombier :<\/strong><\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/h2><\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-5 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"243\" alt=\"Entretien du puits canadien hydraulique Mydatec\" title=\"Entretien du puits canadien hydraulique Mydatec\" src=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/pro-300x243.png\" class=\"img-responsive wp-image-13037\" srcset=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/pro-200x162.png 200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/pro-400x324.png 400w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/pro-600x487.png 600w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/pro-800x649.png 800w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/pro-1200x973.png 1200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/pro.png 1414w\" sizes=\"(max-width: 900px) 100vw, (max-width: 640px) 100vw, 1200px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-7\" style=\"--awb-font-size:20px;--awb-line-height:1.7;\"><div class=\"page\" title=\"Page 24\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ul>\n<li><span style=\"color: #333333;\">\u00a0Inspection et re\u0301paration fuite du circuit hydraulique dans ses parties visibles<\/span><\/li>\n<li><span style=\"color: #333333;\">\u00a0Inspection et nettoyage de l&rsquo;e\u0301changeur de chaleur air \/ eau<\/span><\/li>\n<li><span style=\"color: #333333;\">\u00a0Remplacement du circulateur<\/span><\/li>\n<li><span style=\"color: #333333;\">\u00a0Remplacement du vase d&rsquo;expansion<\/span><\/li>\n<li><span style=\"color: #333333;\">\u00a0Remplacement de la soupape de se\u0301curite\u0301<\/span><\/li>\n<li><span style=\"color: #333333;\">\u00a0Remplacement du manome\u0300tre<\/span><\/li>\n<li><span style=\"color: #333333;\">\u00a0Remplacement du purgeur<\/span><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"fusion-image-element \" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-6 hover-type-none\"><img decoding=\"async\" width=\"300\" height=\"198\" alt=\"Entretien du puits canadien hydraulique Mydatec\" title=\"Entretien du puits canadien hydraulique Mydatec\" src=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Blanc-ete-puits-canadien-freecooling-10-300x198.png\" class=\"img-responsive wp-image-13054\" srcset=\"https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Blanc-ete-puits-canadien-freecooling-10-200x132.png 200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Blanc-ete-puits-canadien-freecooling-10-400x264.png 400w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Blanc-ete-puits-canadien-freecooling-10-600x395.png 600w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Blanc-ete-puits-canadien-freecooling-10-800x527.png 800w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Blanc-ete-puits-canadien-freecooling-10-1200x791.png 1200w, https:\/\/www.mydatec.com\/wp-content\/uploads\/2023\/07\/Blanc-ete-puits-canadien-freecooling-10.png 1414w\" sizes=\"(max-width: 900px) 100vw, (max-width: 640px) 100vw, 1200px\" \/><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-5 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1144px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-7 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-margin-top-small:0px;--awb-margin-right-small:0px;--awb-margin-bottom-small:20px;--awb-margin-left-small:0px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><strong>Entretien de l\u2019e\u0301changeur<\/strong><\/h3><\/div><div class=\"fusion-text fusion-text-8\"><div class=\"page\" title=\"Page 27\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Ve\u0301rifier la proprete\u0301 de l\u2019e\u0301changeur lors de l\u2019e\u0301change de vos filtres et au minimum tous les 6 mois.<\/p>\n<ol>\n<li>Arre\u0302ter votre unite\u0301 de ventilation.<\/li>\n<li>Ouvrir le panneau de fac\u0327ade<\/li>\n<li>Retirer le filtre<\/li>\n<li>Ve\u0301rifier la proprete\u0301 de l\u2019e\u0301changeur et si besoin.\n<ul>\n<li>Utiliser un peigne a\u0300 ailette pour retirer la salete\u0301.<\/li>\n<li>Souffler l\u2019e\u0301changeur a\u0300 l\u2019aide d\u2019un compresseur a\u0300 air.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<p><strong>Ne pas utiliser de produits corrosifs pouvant de\u0301te\u0301riorer l\u2019e\u0301changeur.<\/strong><\/p>\n<ol>\n<li>Remettre le filtre en place<\/li>\n<li>Refermer le panneau<\/li>\n<li>Remettre votre syste\u0300me de ventilation en fonctionnement.<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;width:100%;\"><div class=\"fusion-separator-border sep-double\" style=\"--awb-height:20px;--awb-amount:20px;border-color:#e0dede;border-top-width:1px;border-bottom-width:1px;\"><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-8 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-margin-top-small:0px;--awb-margin-right-small:0px;--awb-margin-bottom-small:20px;--awb-margin-left-small:0px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><strong>Remplacement du circulateur<\/strong><\/h3><\/div><div class=\"fusion-text fusion-text-9\"><div class=\"page\" title=\"Page 27\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ol>\n<li>Mettre votre puits climatique hydraulique hors tension<\/li>\n<li>Ouvrir le capot supe\u0301rieur<\/li>\n<li>De\u0301connecter l\u2019alimentation e\u0301lectrique du circulateur du bornier de raccordement (bornes 4-5-6)<\/li>\n<li>Fermer les vannes repe\u0300res (0) et (7).<\/li>\n<li>Raccorder une e\u0301vacuation a\u0300 la vanne repe\u0300re (2)<\/li>\n<li>Ouvrir la vanne repe\u0300re (2)<\/li>\n<li>Remplacer la pompe<\/li>\n<li>Remplir le circuit hydraulique en respectant la proce\u0301dure paragraphe 9.<\/li>\n<li>Raccorder la nouvelle pompe sur les bornes 4-5-6<\/li>\n<li>Refermer le capot supe\u0301rieur<\/li>\n<li>Remettre votre puits climatique hydraulique sous tension<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"align-self: center;margin-left: auto;margin-right: auto;width:100%;\"><div class=\"fusion-separator-border sep-double\" style=\"--awb-height:20px;--awb-amount:20px;border-color:#e0dede;border-top-width:1px;border-bottom-width:1px;\"><\/div><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-9 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-margin-top-small:0px;--awb-margin-right-small:0px;--awb-margin-bottom-small:20px;--awb-margin-left-small:0px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><strong>Remplacement du vase d\u2019expansion<\/strong><\/h3><\/div><div class=\"fusion-text fusion-text-10\"><div class=\"page\" title=\"Page 27\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ol>\n<li>Mettre votre puits climatique hydraulique hors tension<\/li>\n<li>Ouvrir le capot supe\u0301rieur<\/li>\n<li>Fermer les vannes repe\u0300res (0) et (7).<\/li>\n<li>Raccorder une e\u0301vacuation a\u0300 la vanne repe\u0300re (2)<\/li>\n<li>Ouvrir la vanne repe\u0300re (2)<\/li>\n<li>Remplacer le vase d\u2019expansion<\/li>\n<li>Remplir le circuit hydraulique en respectant la proce\u0301dure paragraphe 9.<\/li>\n<li>Refermer le capot supe\u0301rieur<\/li>\n<li>Remettre le syste\u0300me sous tension<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.84%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.84%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-10 fusion-sep-none fusion-title-text fusion-title-size-three\" style=\"--awb-margin-top-small:0px;--awb-margin-right-small:0px;--awb-margin-bottom-small:20px;--awb-margin-left-small:0px;\"><h3 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><strong>Remplacement du module e\u0301changeur ou du manome\u0300tre<\/strong><\/h3><\/div><div class=\"fusion-text fusion-text-11\"><div class=\"page\" title=\"Page 28\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ol>\n<li>Mettre votre puits climatique hydraulique hors tension<\/li>\n<li>Ouvrir le capot supe\u0301rieur<\/li>\n<li>Fermer les vannes d\u2019isolement (D) et (H) d\u2019entre\u0301e et de sortie du puits canadien.<\/li>\n<li>Vidanger la batterie a\u0300 l\u2019aide d\u2019un re\u0301cipient pouvant contenir la totalite\u0301 du me\u0301lange d\u2019eau glycole\u0301econtenu dans l\u2019e\u0301changeur (environ 10 L).<\/li>\n<li>Remplacer le module e\u0301changeur ou le manome\u0300tre.<\/li>\n<li>Remplir le circuit hydraulique en respectant la proce\u0301dure paragraphe 9.<\/li>\n<li>Refermer le capot supe\u0301rieur<\/li>\n<li>Remettre le syste\u0300me sous tension<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-6 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1144px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div style=\"text-align:center;\"><a class=\"fusion-button button-3d button-xlarge button-custom fusion-button-default button-2 fusion-button-default-span \" style=\"--awb-margin-bottom:0px;--button_accent_color:#ffffff;--button_accent_hover_color:#596301;--button_border_hover_color:#596301;--button_border_width-top:0px;--button_border_width-right:0px;--button_border_width-bottom:0px;--button_border_width-left:0px;--button-border-radius-top-left:50px;--button-border-radius-top-right:50px;--button-border-radius-bottom-right:50px;--button-border-radius-bottom-left:50px;--button_gradient_top_color:#000000;--button_gradient_bottom_color:#000000;--button_gradient_top_color_hover:#f2f4eb;--button_gradient_bottom_color_hover:#f2f4eb;--button_text_transform:var(--awb-typography5-text-transform);--button_typography-letter-spacing:0px;--button_typography-font-family:&quot;Roboto&quot;;--button_typography-font-style:normal;--button_typography-font-weight:500;\" target=\"_self\" href=\"https:\/\/f0c4e0af.sibforms.com\/serve\/MUIFAParrGec1DQCEKzlPXLvzxqBCdbvtsaJy87eolziMUMh5mTz8zNSwuAqDksSYd3O-jx2W5SXr8l2zhetCiwOjsP37kmmJc0393zVzTDCDVjuCngf_HtHPctX6lENXMT7rZ-b4rcibcYn-aAjLbdBA8CUryDSwGXvpjeM72TqN8srSUphes_BVvk-L_oWad7otEQ7xsZXeEb-\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Demander un tarif puits canadien hydraulique<\/span><\/a><\/div><ul style=\"--awb-item-padding-top:20px;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;--awb-circlecolor:#9e9e9e;--awb-circle-yes-font-size:12.32px;\" class=\"fusion-checklist fusion-checklist-1 type-numbered\"><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-yes\">1<\/span><div class=\"fusion-li-item-content\">\n<p><a href=\"https:\/\/www.mydatec.com\/fr\/titre-v-re2020-tutos-de-saisie-des-systemes-mydatec\/\">=&gt; Voir le tuto de saisie RE2020 pour le puits canadien hydraulique MyDATEC<\/a><\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-yes\">2<\/span><div class=\"fusion-li-item-content\">\n<p><a href=\"https:\/\/www.mydatec.com\/fr\/puits-canadien-hydraulique-performance-et-caracteristiques\/\">=&gt; Voir\u00a0les caract\u00e9ristiques techniques et performances du puits canadien hydraulique MyDATEC<\/a><\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-yes\">3<\/span><div class=\"fusion-li-item-content\">\n<p><a href=\"https:\/\/www.mydatec.com\/fr\/puits-canadien-hydraulique-mydatec-installation\/\">=&gt; en savoir plus sur l&rsquo;installation du puits canadien hydraulique MyDATEC<\/a><\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-yes\">4<\/span><div class=\"fusion-li-item-content\">\n<p><a href=\"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/\">=&gt; En savoir plus sur l&rsquo;entretien du puits canadien hydraulique MyDATEC<\/a><\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-yes\">5<\/span><div class=\"fusion-li-item-content\">\n<p><a href=\"https:\/\/www.mydatec.com\/fr\/commande-et-pilotage-du-puits-canadien-hydraulique-mydatec\/\">=&gt; En savoir plus sur le pilotage du puits canadien hydraulique MyDatec<\/a><\/p>\n<\/div><\/li><li class=\"fusion-li-item\" style=\"\"><span class=\"icon-wrapper circle-yes\">6<\/span><div class=\"fusion-li-item-content\">\n<p><a href=\"https:\/\/www.mydatec.com\/fr\/puits-canadien-hydraulique-mydatec-fonctionnement\/\">=&gt; Voir le principe de fonctionnement du puits canadien hydraulique MyDATEC en images<\/a><\/p>\n<\/div><\/li><\/ul><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":10,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"footnotes":""},"class_list":["post-12864","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>puits canadien hydraulique de MyDATEC- entretien<\/title>\n<meta name=\"description\" content=\"Tout savoir sur l&#039;entretien du puits canadien hydraulique MyDATEC, du remplacement du filtre, au nettoyage des condensats.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"puits canadien hydraulique de MyDATEC- entretien\" \/>\n<meta property=\"og:description\" content=\"Tout savoir sur l&#039;entretien du puits canadien hydraulique MyDATEC, du remplacement du filtre, au nettoyage des condensats.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/\" \/>\n<meta property=\"og:site_name\" content=\"MyDATEC\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-18T07:56:03+00:00\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"71 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/entretien-du-puits-canadien-hydraulique-mydatec\\\/\",\"url\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/entretien-du-puits-canadien-hydraulique-mydatec\\\/\",\"name\":\"puits canadien hydraulique de MyDATEC- entretien\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/#website\"},\"datePublished\":\"2023-07-10T11:28:32+00:00\",\"dateModified\":\"2023-07-18T07:56:03+00:00\",\"description\":\"Tout savoir sur l'entretien du puits canadien hydraulique MyDATEC, du remplacement du filtre, au nettoyage des condensats.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/entretien-du-puits-canadien-hydraulique-mydatec\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/entretien-du-puits-canadien-hydraulique-mydatec\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/entretien-du-puits-canadien-hydraulique-mydatec\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"puits canadien hydraulique de MyDATEC- entretien\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/\",\"name\":\"MyDATEC\",\"description\":\"La solution thermodynamique\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/#organization\",\"name\":\"MyDatec\",\"url\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.mydatec.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logo-mydatec.jpg\",\"contentUrl\":\"https:\\\/\\\/www.mydatec.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logo-mydatec.jpg\",\"width\":434,\"height\":351,\"caption\":\"MyDatec\"},\"image\":{\"@id\":\"https:\\\/\\\/www.mydatec.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.linkedin.com\\\/in\\\/MyDATEC\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"puits canadien hydraulique de MyDATEC- entretien","description":"Tout savoir sur l'entretien du puits canadien hydraulique MyDATEC, du remplacement du filtre, au nettoyage des condensats.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/","og_locale":"fr_FR","og_type":"article","og_title":"puits canadien hydraulique de MyDATEC- entretien","og_description":"Tout savoir sur l'entretien du puits canadien hydraulique MyDATEC, du remplacement du filtre, au nettoyage des condensats.","og_url":"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/","og_site_name":"MyDATEC","article_modified_time":"2023-07-18T07:56:03+00:00","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"71 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/","url":"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/","name":"puits canadien hydraulique de MyDATEC- entretien","isPartOf":{"@id":"https:\/\/www.mydatec.com\/fr\/#website"},"datePublished":"2023-07-10T11:28:32+00:00","dateModified":"2023-07-18T07:56:03+00:00","description":"Tout savoir sur l'entretien du puits canadien hydraulique MyDATEC, du remplacement du filtre, au nettoyage des condensats.","breadcrumb":{"@id":"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.mydatec.com\/fr\/entretien-du-puits-canadien-hydraulique-mydatec\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.mydatec.com\/fr\/"},{"@type":"ListItem","position":2,"name":"puits canadien hydraulique de MyDATEC- entretien"}]},{"@type":"WebSite","@id":"https:\/\/www.mydatec.com\/fr\/#website","url":"https:\/\/www.mydatec.com\/fr\/","name":"MyDATEC","description":"La solution thermodynamique","publisher":{"@id":"https:\/\/www.mydatec.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mydatec.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.mydatec.com\/fr\/#organization","name":"MyDatec","url":"https:\/\/www.mydatec.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.mydatec.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.mydatec.com\/wp-content\/uploads\/2022\/01\/logo-mydatec.jpg","contentUrl":"https:\/\/www.mydatec.com\/wp-content\/uploads\/2022\/01\/logo-mydatec.jpg","width":434,"height":351,"caption":"MyDatec"},"image":{"@id":"https:\/\/www.mydatec.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.linkedin.com\/in\/MyDATEC"]}]}},"_links":{"self":[{"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/pages\/12864","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/comments?post=12864"}],"version-history":[{"count":5,"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/pages\/12864\/revisions"}],"predecessor-version":[{"id":13879,"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/pages\/12864\/revisions\/13879"}],"wp:attachment":[{"href":"https:\/\/www.mydatec.com\/fr\/wp-json\/wp\/v2\/media?parent=12864"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}