Hydraulic heat exchanger

puit-canadien

Optimise the performances of your CMV by retrieving calories or cold energy from the soil, thanks to a water/air battery and a water loop buried underground (geothermal detector). Enjoy the system’s automatic adjustment via touch screen.

puit-ecran

Exchanger page on the touch screen

BENEFITS

  • Independent adjustment
  • Compatible with double-flow systems double flow
  • Display of the number of hot and cold working hours and the thermal performance of the hydraulic heat exchanger

COMPLIANCE

  • Passive sealed houses
  • BEPOS / RT2012

Application

  • House (new or renovation)

Set-up

  • Place on the fresh air intake duct of the double flow ventilation system.
  • Ready-made kit (underground sensor + glycol + connectors)
  • Electric power supply 230VAC (1.5mm²)
  • Touch screen connection via 4 0.5mm² conductors (12V + Modbus connection) from the heat exchanger

Description

MODES OF THE HYDRAULIC HEAT EXCHANGER
puit-1 Pause
puit-2 Hot Mode
puit-3 Cold Mode
puit-4 Anti-jamming Mode
PARAMETER PAGE
puit-5 Temperature instructions page
puit-6 Working duration page
puit-7 Adjustment of the parameters on page
puit-8 Information / Help

Range

DESIGNATION REFERENCE
Hydraulic underground heat exchanger HYDRAULIC_HEAT_EXCHANGER_KIT

 

Technical features

puit-caracteristiques-1Air supply loss of charge in the G-2000 hydraulic heat exchanger

puit-caracteristiques-2

 

Caractéristiques techniques

 G-2000
Weight  15 kg
Connection diameter of air ducts Operation Ø200 et Ø250
temperature -22 °C à 60 °C
Heating power up to Jusqu’à 2 kW (*)
Cooling power up to Jusqu’à 2.1 kW (*)
Annual saving Jusqu’à 4100 kWh (*)
Hydraulic interface 3/4
Condensation discharge interface Ø32

* Hypotheses

Clay sole saturated with water
Climate zone : H2d
100 ml sensor
Depth sensor 4m
Air flow : 400 m3/h
Instructions of the Heat Exchanger: 18°C
Instructions of the Cooling Exchanger : 22°C

puit-canadien-en