Automatic bypass

((to be used with an air supply heat exchanger, not supplied))

   bypass

Optimise the performance of your CMV by making smart use of the air supplied by your heat exchanger, so as to heat up or cool your house.

BENEFITS

  • Smart management of your air supply heat exchanger
  • Optimised temperature and duration

Application

  • House
  • Tertiary
    • Double Flow ventilation system
    • Ventilation system via air blowing

Set-up

  • Flat assembly is mandatory
  • 2 Air Supply Inputs Ø200 / 1 Air Supply Output Ø200
  • Power supply 230 VAC (1.5mm²)
  • Screen connection via 4 0.5mm² conductors (12V + Modbus connection) from the bypass

Description

bypass-description

The automatic ByPASS of MyDATEC is a three-way air distributor with two electric control points managed via touch control. Based on the heating and cooling temperature, the parameters of which can be set independently, the adjustment allows you to choose one option over the other by comparing temperatures, so as to ensure heating or cooling optimisation.

Range

DESIGNATION REFERENCE
Automatic Bypass Ø200 KIT_BYPASS_AUTO_D200

 

Technical features

Page Bypass sur l’écran tactile

bypass-ecran

Bypass page on the touch screen
bypass-fonctionnement

LEGENDE

————————- Temperature of air supply heat exchanger

————————- Temperature of external air

• Mode 1 : Heating via air recovery on the heat exchanger
External temperature < Heating instructions temperature and Temperature of Heat exchangers > Temperature External air
• Mode 2 : Recovery pace
External temperature < Heating temperature and Temperature of the Heat exchanger < Temperature of External air
• Mode 3 : Recovery pace
Heating temperature < External temperature < Cooling temperature • Mode 4 : PRecovery pace External temperature > Cooling temperature and Temperature of the Heat exchangers > Temperature External air
• Mode 5 : Cooling via air recovery on the heat exchanger
External temperature > Cooling temperature and Temperature of the Heat exchangers < Temperature External air